Patent ductus arteriosus closure using an Amplatzer ventricular septal defect closure device in adulthood

Loua Hattach, Kawtar Afrikh, Nadia Fellat, Rokya Fellat
Cardiology Department A, Hopital Ibn Sina, Rabat, Morocco

Patent ductus arteriosus (PDA) is a persistent communication between the descending thoracic aorta and the pulmonary artery that results from failure of normal physiologic closure of the fetal ductus. It is one of the more common congenital heart defects. The PDA closure is the main treatment and can be surgical or percutaneous. The trancatheter approach proved its efficacy and safety all over the past 20 years and a variety of devices have been developed and are now available. This report describes a transcatheter closure of a PDA on an 18-year-old girl with features suggestive of a large PDA. While we intended to close the PDA using an Amplatzer device occluder (ADO), we changed our approach and used a ventricular septal defect (VSD) Amplatzer occluder instead.

Keywords: Adult, Patent ductus arteriosus, Percutaneous closure, Ventricular septal defect device occlude

Accepted: April 10, 2019; Published: February 28, 2020  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Hattach L, Afrikh K, Fellat N, Fellat R. Patent ductus arteriosus closure using an Amplatzer ventricular septal defect closure device in adulthood. Cor Vasa. 2020;62(1):72-74. doi: 10.33678/cor.2019.045.
Download citation

References

  1. Thanopoulos BD, Brili SD, Toutouzas PK. Patent ductus arteriosus and aortopulmonary window. In: Gatzoulis MA, Webb GD, Daubeney PEF (Eds.). Diagnosis and Management of Adult Congenital Heart Disease. 2nd edition. London, Elsevier, 2010:256-260. Go to original source...
  2. Garson A Jr, Bricker JT, Fisher DJ, Neish SR, et al. The Science & Practice of Pediatric Cardiology, 2nd edition, volume I. Baltimore: Williams & Wilkins, 1998:1181-1182.
  3. Portsmann W, Wierny L, Warnke H. Closure of persistent ductus arteriosus without thoracotomy. Ger Med Monthly 1967;12:259-261.
  4. Rashkind WJ, Cuaso CC. Transcatheter closure of a patent ductus arteriosus: Successful use in a 3.5-kg infant. Pediatr Cardiol 1979;1:3-7. Go to original source...
  5. Krichenko A, Benson LN, Burrows P, et al. Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 1989;63:877-880. Go to original source... Go to PubMed...
  6. Fernando R, Koranne K, Loyalka P, et al. Patent ductus arteriosus closure using an amplatzer TM ventricular septal defect closure device. Exp Clin Cardiol 2013;18:e50-e54.
  7. Atiq M, Aslam N, Kazmi KA. Transcatheter closure of small-to-large patent ductus arteriosus with different devices: Queries and challenges. J Invasive Cardiol 2007;19:295-298. Go to PubMed...

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.





Cor et Vasa

You are accessing a site intended for medical professionals, not the lay public. The site may also contain information that is intended only for persons authorized to prescribe and dispense medicinal products for human use.

I therefore confirm that I am a healthcare professional under Act 40/1995 Coll. as amended by later regulations and that I have read the definition of a healthcare professional.